SourcingAI

Electrostatic generators

I have found results from10000+products and3000+suppliers aboutElectrostatic generators

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Basic Diesel Generator
Self-Starting Diesel Generator
High Pressure Discharge Type
Micro-Computer Control Automatic Diesel Generator
Accuracy Grade: 0.5
Display: Digital
Control: Manual Control
Power Source: AC220V
Conditions of Use: Land Use
Usage: Emergency Crew
AC Single Phase
Cooling Method: Wind Cooling
Installation Method: Fixed
Generator Type: Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Speed: Speed
Conditions of Use: Land Use
Landuse Type of Unit: Ordinary
AC Rotating Exciter
Load Way: Electronic Load
Loading Method: Dynamic Load
Function: Steam Boilers
Fuel: Gas-Fired
Installation: Packaged Boiler
Structure: Fire Tube
Steam and Water
Water Circulation: Natural Circulation
Drum Placement: Vertical Boiler
Pressure: Low Pressure
Manufacturing Level: B
Chamber Combustion Boiler
Certification: ISO9001
Dielectric Material: Ceramic Plate
Gas: Air
Frequency: 50-60Hz
Application: Power
Phase: Single
Frequency Characteristics: Power Frequency
Accuracy Grade: 1
Control: Computer Control
Usage: Common Units
Usage: Standby Unit
Usage: Industrial
Usage: Vehicle
Usage: Power Station
Usage: Single-phase Transformer
SMT Production Line
Usage: Printing Workshop
Usage: Computer Room
Electronic Component Maintenance Room
Combustible & Explosive Area
AC Three Phase
Installation Method: Portable
Cooling Method: Air Cooled
Cooling Method: Air-Cooling
Oil-immersed Type Transformer
Cooling Method: Wind Cooling
Speed: 1500rpm
Speed: 1800rpm
Speed: 3000rpm
Speed: 3600rpm
Landuse Type of Unit: Low Noise
Landuse Type of Unit: Automation Type
Low Noise Automation Type
Installation: Wall-Mounted
Certification: RoHS
Certification: CE
Certification: ISO9001-2000
Application: Electronic

Sourcing guidance for Electrostatic Generators

What are the key technical specifications to consider when sourcing an electrostatic generator?

Buyers must prioritize output voltage stability and current control. For industrial applications like powder coating or flocking, a range of 30kV to 100kV is standard. Ensure the device features adjustable polarity (positive or negative) and high-precision digital displays for real-time monitoring. Additionally, verify the insulation resistance levels to prevent internal arcing, which is critical for long-term operational reliability.

Which safety and compliance standards are mandatory for international trade of these devices?

Due to the high-voltage nature, products must adhere to CE (LVD and EMC directives) for the European market or UL/ETL certification for North America. For hazardous environments, ATEX or IECEx explosion-proof certification is non-negotiable. Ensure the supplier provides a Certificate of Conformity (CoC) and that the equipment includes automatic discharge circuits to safely bleed off residual high voltage after shutdown.

How do usage scenarios dictate the choice of technology (Van de Graaff vs. Solid-State)?

Van de Graaff generators are primarily suited for educational demonstrations and physics labs due to their visible belt mechanism. Conversely, Solid-state (electronic) generators are preferred for industrial processes like smoke precipitation, static elimination, or X-ray power supplies because they offer higher reliability, compact footprints, and precise electronic regulation without moving parts that wear out.

What maintenance and durability factors should be evaluated?

Focus on the quality of the high-voltage multiplier and the encapsulation material (such as high-grade epoxy resin) which protects against humidity and dust. Ask for the Mean Time Between Failures (MTBF) data. For belt-driven models, check the replacement cycle of the charging belt and the availability of spare brushes. Industrial units should have an IP54 or higher rating to withstand factory environments.

Cross-Border Procurement & Risk Management for High-Voltage Equipment

How can I mitigate transaction risks when purchasing high-value industrial electronics?

Utilize Secured Trading Services on platforms like Made-in-China.com to ensure payment is only released upon confirmation of delivery. Always conduct a pre-shipment inspection (PSI) via third-party agencies like SGS or Intertek to verify that the voltage output matches the technical datasheet before the balance payment is made.

What are the specific shipping requirements for electrostatic generators?

These units often contain sensitive electronic components and high-voltage capacitors. Ensure the supplier uses anti-static vacuum packaging and shock-absorbent wooden crates. Since they may be classified as 'Magnetic Goods' or 'Sensitive Electronics' by airlines, verify if a Magnetic Inspection Report is required for air freight, or opt for sea freight (LCL/FCL) to reduce costs and handling risks.

How should I negotiate technical support and warranty terms with overseas suppliers?

Negotiate a minimum 12-24 month warranty that includes free replacement of core high-voltage modules. Demand English-language technical manuals and video operation guides. For complex industrial systems, insist on remote technical support via video call or the provision of critical wear-and-tear spare parts (like ionizing needles or cables) included in the initial purchase price.

What customs and tariff considerations apply to this category?

Identify the correct HS Code (typically under 8543.70) to determine applicable import duties. Be aware of anti-dumping duties or specific trade barriers in your region. Ensure the Commercial Invoice and Packing List clearly state the 'intended use' (e.g., industrial research or manufacturing) to facilitate smoother customs clearance and potential duty exemptions for scientific equipment.

Related queries